Removing Leica Meter: Detaching From Camera Shoe

how to remove leica meter from camera shoe

If you want to remove a Leica light meter from a camera, you'll need to first identify the model of the camera and the light meter. In the case of a Leica MR meter attached to an M3 body, align the red marker on the meter's control dial with the inverted L-shaped line on the side of the meter. Pull up and then rotate the dial in the direction of the horizontal line to unlock the meter from the camera shoe. For a Leica Light Meter MC attached to a Leica M2, align the mark/line on the side of the dial with the arrow on the meter, then lift the dial and pull out the meter.

Characteristics Values
Meter Type MR
Camera Type M3
Steps to Remove 1. Line up the marker on the meter's control dial with the inverted L-shaped line on the side of the meter. 2. Pull up and rotate the dial in the direction of the horizontal line to unlock. 3. Slide the meter back from the shoe.

shundigital

Align the mark/line on the side of the dial with the arrow on the meter

To remove a Leica meter from a camera shoe, one of the steps involves aligning the mark or line on the side of the dial with the arrow on the meter. Here is a detailed, step-by-step guide to performing this action:

Firstly, locate the dial on the Leica meter. This is a small, circular knob that is used to adjust settings on the meter. It is usually located on the front or top of the meter, depending on the model. The dial should be easy to identify as it will have markings indicating different shutter speed settings. Once you have located the dial, look for a mark or line on its side. This mark or line is usually small and subtle, so you may need to examine the dial closely. It could be in the form of a line, an inverted "L" shape, or an arrow, depending on the model of your Leica meter.

Next, locate the arrow on the meter. This arrow is typically found on the meter's control panel, which is the part of the meter that displays the light readings and other information. The arrow will be pointing towards one of the markings on the control panel, indicating the current setting or mode of the meter. It is important to note that the arrow may be small and delicate, so a careful eye is needed to spot it.

Now, adjust the dial so that the mark or line on its side aligns with the arrow on the meter. This step requires precision and attention to detail. Carefully turn the dial clockwise or anticlockwise until the mark or line matches the position of the arrow. It is important to take your time and make small adjustments to ensure an accurate alignment. Once you have achieved this alignment, the meter should be ready to be removed from the camera shoe.

At this point, the meter should be unlocked and can be safely detached from the camera. To do this, gently lift the dial upwards and pull the meter out of the camera shoe. It may require a slight wiggling motion to detach it completely. Be cautious during this step to avoid applying excessive force, as it may damage the delicate components of the meter or camera.

By following these steps, you will be able to successfully align the mark or line on the side of the dial with the arrow on the meter, allowing you to safely remove the Leica meter from your camera shoe. Remember to handle the equipment with care and perform each step with precision to ensure the best outcome.

shundigital

Lift the dial up

To remove a Leica meter from your camera shoe, you must first set your Leica M to BULB. Next, set your Leicameter to BULB, lifting the shutter knob towards you and continuing to rotate the dial counter-clockwise to slower speeds. This will ensure the knob stays retracted.

Now, the important part: lift the dial up.

Once the dial is lifted, continue with the removal process by sliding the Leicameter onto the Leica's accessory shoe. Rotate the Leicameter's knob back towards BULB, and you will feel the detents from the camera's dial. You will also see the camera's dial turning with the Leicameter's knob.

If you are unsure where the dial is, refer to your Leicameter's manual or locate the meter's control dial. This will usually have a marker, often in red, that you can line up with the inverted L-shaped line on the side of the meter.

Lifting the dial is a crucial step in removing the Leicameter from your camera shoe. It ensures that the Leicameter's knob is retracted and able to clear the camera's accessory shoe during the removal process. Once the dial is lifted, you can slide the Leicameter onto or off the camera shoe as needed.

Remember to always handle your camera equipment with care to avoid any accidental damage.

shundigital

Pull the meter out

To pull the meter out, you must first set the Leica camera to bulb mode. This will allow you to lift the meter's knob and rotate it towards the slowest speeds, such as 15 seconds. This action will decouple the knob from the camera's speed dial. Once decoupled, you can then slide the meter off the camera towards the rear.

It is important to note that the meter's knob will only lift if it is set to bulb or slower. Therefore, make sure to follow the steps outlined above when attaching or removing the meter to ensure that you do not force anything and risk damaging your equipment.

Additionally, when removing the meter, ensure that you lift the dial and align the mark or line on the side of the dial with the arrow on the meter before pulling it out. This will ensure that you do not damage the camera or meter during removal.

By following these steps, you can safely remove the light meter from your Leica camera without causing any harm to the equipment.

shundigital

Rotate the dial to the horizontal line to unlock

To remove the Leica meter from your camera shoe, you must first set your Leica M to BULB. Next, set your Leicameter to BULB, which will cause the Leica M's shutter knob to lift towards you. Continue to rotate the Leicameter's dial counter-clockwise to slower speeds, such as 15 seconds, so that the knob stays retracted.

Now, you can slide the Leicameter off the Leica M's accessory shoe. To do this, rotate the Leicameter's dial back towards the BULB setting. At this point, the Leica M's shutter knob will drop, and its pins will engage with the Leicameter's dial.

Finally, continue rotating the Leicameter's dial to the horizontal line to unlock it. Then, the Leicameter should slide back from the shoe normally.

Be careful not to force anything, as you don't want to risk harming your camera.

shundigital

The meter should slide back normally

To remove the Leica meter from the camera shoe, you will need to first unlock it by aligning the marker on the meter's control dial with the inverted L-shaped line on the side of the meter. Once you have done this, pull up on the meter and then rotate it in the direction of the horizontal line of the inverted L. After unlocking it, the meter should slide back normally from the shoe.

  • Ensure that the camera is in a stable position and that you are working in a well-lit area to easily see the meter and its components.
  • Locate the inverted L-shaped line on the side of the meter. This line will be used to align the marker on the control dial.
  • Identify the marker on the meter's control dial. This marker may be red or a similar colour, and it should be able to line up with the inverted L-shaped line.
  • Carefully pull up on the meter. You may need to apply a gentle amount of force, but be cautious not to pull too hard to avoid damaging the meter or the camera.
  • Once the meter is pulled up, rotate it in the direction of the horizontal line of the inverted L. This will unlock the meter from the camera shoe.
  • After unlocking the meter, you should now be able to slide it back normally from the shoe. Be gentle and use a slow and steady motion to avoid any accidental damage.

By following these steps, you will be able to safely remove the Leica meter from the camera shoe without causing any harm to the equipment.

Frequently asked questions

There is a line on the side of the meter that looks like an inverted L. Line up the marker on the meter's control dial with that line and pull up and then rotate in the direction of the horizontal line to unlock it. Then it should slide back from the shoe normally.

Align the mark/line on the side of the dial with the arrow on the meter. Then lift the dial up and pull the meter out.

Use a Leica LEICAMETER MR-4. The button on the MR-4 is designed to stay clear of these cameras' rewind cranks.

The first Leica light meters, the LEICAMETER and LEICAMETER 2, have simple, universal feet that slide into any camera's accessory shoe. They are not connected to any camera settings. You simply have to read the measurements and transfer the aperture and shutter speed settings to the camera.

Written by
Reviewed by
Share this post
Print
Did this article help you?

Leave a comment